Batch Create Connector
Version 24.2.9039
Version 24.2.9039
Batch Create Connector
Overview
In CData Arc, data travels through flows as Messages that consist of a body and metadata headers. For example, if one connector passes a file to another, the file is transmitted as a Message that contains the file in the body and metadata about the file and associated connectors as headers. Messages can be grouped together in Batch Groups, which allow multiple messages to travel together as a single unit. Some uses for Batch Groups include moving data between systems and processing multiple purchase orders at once. When a Message is part of a Batch Group, it is referred to as a Batch Message.
The Batch Create connector produces Batch Groups based on Messages that arrive in the Send folder (the Input tab of the connector settings pane). When a Batch Group is created, it is passed down the flow through the Output tab, where it can be processed by other connectors as needed.
Note: The Batch Create connector can only accept individual messages as inputs. If the connector receives an existing Batch Group as an input, it throws an error message.
Connector Configuration
This section contains all of the configurable connector properties.
Settings Tab
Configuration
Settings that determine how the connector can be accessed.
- コネクタId コネクタの静的な一意の識別子。
- コネクタの種類 コネクタ名とその機能の説明が表示されます。
- コネクタの説明 コネクタとフローにおけるロールについて自由形式の説明を記載するオプションのフィールド。
Advanced Settings
Settings that specify Batch Grouping options.
- Correlation Id Header The connector looks for headers that match the header name you enter, then groups messages according to the values they have assigned to that header. See Correlation Id Header Example for details.
- Max Batch Size The maximum number of messages to include in a Batch Group. Any messages in excess of this number wait until the next sending interval. For example, if this is set to 5, and seven messages arrive in the send folder, the connector creates one Batch Group of five messages and adds the final two to the next scheduled Batch Group.
- Min Batch Size The minimum number of messages that must be present to create a Batch Group. For example, if this is set to five, and three messages arrive in the Send folder, the connector does not create a Batch Group from those messages (even if the specified sending interval passes) until at least two more messages arrive.
Message
- Sent フォルダに保存 チェックすると、コネクタで処理されたファイルをコネクタのSent フォルダにコピーします。
- Sent フォルダのスキーム 選択された時間間隔に従ってSent フォルダ内のメッセージをグループ化するようコネクタに指示します。例えば、Weekly オプションを選択すると、コネクタは毎週新しいサブフォルダを作成してその週のすべてのメッセージをそのフォルダに格納します。ブランクに設定すると、コネクタはすべてのメッセージをSent フォルダに直接保存します。多くのメッセージを処理するコネクタの場合、サブフォルダを使用するとメッセージが整理されてパフォーマンスが向上します。
Logging
- Log Level The verbosity of logs generated by the connector. When you request support, set this to Debug.
- Log Subfolder Scheme Instructs the connector to group files in the Logs folder according to the selected interval. For example, the Weekly option instructs the connector to create a new subfolder each week and store all logs for the week in that folder. The blank setting tells the connector to save all logs directly in the Logs folder. For connectors that process many transactions, using subfolders helps keep logs organized and improves performance.
- Log Messages Check this to have the log entry for a processed file include a copy of the file itself. If you disable this, you might not be able to download a copy of the file from the Input or Output tabs.
Miscellaneous
Miscellaneous settings are for specific use cases.
- Other Settings Enables you to configure hidden connector settings in a semicolon-separated list (for example,
setting1=value1;setting2=value2
). Normal connector use cases and functionality should not require the use of these settings.
Automation Tab
Automation Settings
Settings related to the creation and sending of Batch Groups.
- Enable automation If selected, the connector automatically creates Batch Groups following the settings below. If cleared, the connector does not create Batch Groups until you manually trigger it.
- Send If selected, the connector automatically creates Batch Groups from messages as soon as they arrive in the Send folder (Input tab) as long as other set criteria are met.
- Scheduled Send If selected, the connector uses a scheduled interval to create Batch Groups from messages that arrive in the Send folder.
- Send Interval The interval at which to create Batch Groups. Only available if Scheduled Send is enabled.
- 毎時何分 時間単位のスケジュールの分オフセット。上記の受信間隔の設定が Hourly に設定されている場合にのみ適用されます。例えば、この値を5 に設定すると、自動的に1:05、2:05、3:05 のようにダウンロードを行います。
- 時 試行が行われる時刻。上記の受信間隔の設定が Daily 、Weekly、または Monthly に設定されている場合にのみ適用されます。
- 曜日/日付 試行が行われる日。上記の受信間隔の設定が Weekly または Monthly に設定されている場合にのみ適用されます。
- 分 ダウンロードを試行するまでの待機時間。上記の受信間隔の設定が Minute に設定されている場合にのみ適用されます。
- Cron 式 いつ試行するかを決定するcron 式を表す5つの欄の文字列。上記の受信間隔の設定が Advanced に設定されている場合にのみ適用されます。
Performance
コネクタへのリソースの割り当てに関する設定。
- 最大ワーカー数 このコネクタでファイルを処理するためにスレッドプールで消費されるワーカースレッドの最大数。設定された場合、これは設定 > オートメーションページのデフォルト設定をオーバーライドします。
- 最大ファイル数 コネクタに割り当てられた各スレッドが送信するファイルの最大数。設定された場合、これは設定 > オートメーションページのデフォルト設定をオーバーライドします。
アラートタブ
アラートとサービスレベル(SLA)の設定に関連する設定。
コネクタのE メール設定
サービスレベル(SLA)を実行する前に、通知用のE メールアラートを設定する必要があります。アラートを設定をクリックすると、新しいブラウザウィンドウで設定ページが開き、システム全体のアラートを設定することができます。詳しくは、アラートを参照してください。
サービスレベル(SLA)の設定
サービスレベルでは、フロー内のコネクタが送受信すると予想される処理量を設定し、その量が満たされると予想される時間枠を設定できます。CData Arc は、サービスレベルが満たされていない場合にユーザーに警告するE メールを送信し、SLA を At Risk(危険) としてマークします。これは、サービスレベルがすぐに満たされない場合に Violated(違反) としてマークされることを意味します。これにより、ユーザーはサービスレベルが満たされていない理由を特定し、適切な措置を講じることができます。At Risk の期間内にサービスレベルが満たされなかった場合、SLA はViolated としてマークされ、ユーザーに再度通知されます。
サービスレベルを定義するには、予想処理量の条件を追加をクリックします。
- コネクタに個別の送信アクションと受信アクションがある場合は、ラジオボタンを使用してSLA に関連する方向を指定します。
- 検知基準(最小)を、処理が予想されるトランザクションの最小値(量)に設定し、毎フィールドを使用して期間を指定します。
- デフォルトでは、SLA は毎日有効です。これを変更するには、毎日のチェックをOFF にし、希望する曜日のチェックをON にします。
- 期間終了前にステータスを’At Risk’ に設定するタイミングを使用して、SLA がAt Risk としてマークされるようにします。
- デフォルトでは、通知はSLA が違反のステータスになるまで送信されません。これを変更するには、‘At Risk’ 通知を送信のチェックをON にします。
次の例は、月曜日から金曜日まで毎日1000ファイルを受信すると予想されるコネクタに対して構成されたSLA を示しています。1000ファイルが受信されていない場合、期間終了の1時間前にAt Risk 通知が送信されます。
Correlation Id Header Example
When you enter a header name in the Correlation Id Header field, the connector looks for headers that match the name you enter, then groups messages according to the values they have assigned to that header. For example, the following table displays six incoming messages:
MessageId | Filename | Header | Header Value |
---|---|---|---|
1 | test1.txt | Batch-Correlation-Id | 001 |
2 | test2.txt | Batch-Correlation-Id | 001 |
3 | test3.txt | Batch-Correlation-Id | 002 |
4 | test4.txt | Batch-Correlation-Id | 002 |
5 | test5.txt | ||
6 | test6.txt |
If you enter Batch-Correlation-Id in the Correlation Id Header field, the connector creates three Batch Groups of these messages:
- The first batch group contains the messages with MessageId 1 and 2, since they both have the value
001
for the Batch-Correlation-Id header. - The second batch group contains messages with MessageId 3 and 4, since they both have the value
002
for the header. - The third batch group contains messages 5 and 6, since neither of them has the Batch-Correlation-Id header.