SSIS Components for SAP ByDesign

Build 24.0.9060

Establishing a Connection

Enabling SSIS in Visual Studio 2022

If you're using Visual Studio 2022, you will need to install the SQL Server Integration Services Projects extension to use SSIS.

  1. Navigate to Extensions > Manage Extensions.
  2. In the Manage Extensions window's search box, search for "SQL Server Integration Services Projects 2022" and select the extension in the list.
  3. Click Download.
  4. Close Visual Studio and run the downloaded Microsoft.DataTools.IntegrationServices.exe installer. Proceed through the installer with default settings.
  5. Open Visual Studio. There should now be an "Integration Services Project" project template available.

Adding the SAP ByDesign Connection Manager

Create a new connection manager as follows:

  1. Create a Visual Studio project with the "Integration Services Project" template.
  2. In the project, right-click within the Connection Managers window and select New Connection from the menu.
  3. In the Description column, select CData SAP ByDesign Connection Manager and click Add...
  4. Configure the component as described in the next section.

Alternatively, if you have an existing project and CData SAP ByDesign Source or CData SAP ByDesign Destination:

  1. Right-click your CData SAP ByDesign source or destination component in your data flow
  2. Select Edit... to open an editor window.
  3. Click the New... button next to the Connection manager: dropdown selector to create a connection manager.
  4. Configure the component as described in the next section.

This section documents how to provide authentication for your account and service type and then connect.

Authenticate a SAPByDesign Account

Set the following connection properties to connect to SAP ByDesign.

Connect to a Analytical Service

  • Url: Set this to the Url of your SAP ByDesign site. For example, https://test.sapbydesign.com.
  • ServiceType: If you want to retrieve the reports of a analytical service, specify ServiceType=AnalyticsService;.
  • ServiceName: The name of the service you want to retrieve data from. Only none or one service must be specified. If you want to specify a list of services, see BrowsableSchemas.

    If you're not sure what service to specify, you can always query the sys_schemas to list available services.

  • User: Set this to the username of your account.
  • Password: Set this to the password of your account.

Analytical Service Connection String Example:

Url=https://test.sapbydesign.com;ServiceType=AnalyticsService;ServiceName=cc_home_analytics.svc;User=Test;Password=test;

Connect to a Custom Service

  • Url: Set this to the Url of your SAP ByDesign site. For example, https://test.sapbydesign.com.
  • ServiceType: If you have a custom service you want to retrieve data from, specify ServiceType=CustomService;.
  • ServiceName: The name of the service you want to retrieve data from. Only none or one service must be specified. If you want to specify a list of services, see BrowsableSchemas.

    If you're not sure what service to specify, you can always query the sys_schemas to list available services.

  • User: Set this to the username of your account.
  • Password: Set this to the password of your account.

Custom Service Connection String Example:

Url=https://test.sapbydesign.com;ServiceType=CustomService;ServiceName=khsalesorder;User=Test;Password=test;

Connect to the ODataDataSource API

  • Url: Set this to the Url of your SAP ByDesign site. For example, https://test.sapbydesign.com.
  • ServiceType: If you want to query OData Data Source API( odata/analytics/ds) , specify ServiceType=ODataDataSource.
  • ServiceName: The name of the service you want to retrieve data from. Only none or one service must be specified. If you want to specify a list of services, see BrowsableSchemas.

    If you're not sure what service to specify, you can always query the sys_schemas to list available services.

  • User: Set this to the username of your account.
  • Password: Set this to the password of your account.

ODataDataSource Connection String Example:

Url=https://test.sapbydesign.com;ServiceType=ODataDataSource;ServiceName=Customer.svc;User=Test;Password=test;

Add a new custom ODATA service

  • In the SAP ByDesign work center view, click on "Application and User Management".
  • Select "OData Services".
  • In the dropdown list, select "Custom OData Services".
  • Now you should see a list of your current custom services. To add a new one click on "New".

SAP ByDesign URL Restrictions

The SAP ByDesign component enforces URL restrictions to avoid exceeding the maximum of allowed URI length, which causes the service to throw "URI Too Long" error"

By default, the length of the columns in the projection is limited to 1000 characters. If the columns selected in the projection surpass this limit, the driver drops the projection specification and retrieves all fields. This may impact performance because of service response delay and increased payload.

In the case of the analytical service (ServiceType=AnalyticsService), the driver throws an error indicating you must reduce the number of columns in the projection. In addition, the server-side filter length is restricted to 1000 characters for the same reasons. If the generated filter length surpasses this limit, the driver drops the additional filters and handles them client-side.

In SAP ByDesign, you can configure or disable these limitations by using the MaxSelectLength and MaxFilterLength hidden connection properties. These properties both default to 1000 characters. If your service does not have these restrictions, set the properties to -1 to disable the length limitations.

Copyright (c) 2024 CData Software, Inc. - All rights reserved.
Build 24.0.9060