Establishing a Connection
Enabling SSIS in Visual Studio 2022
If you're using Visual Studio 2022, you will need to install the SQL Server Integration Services Projects extension to use SSIS.
- Navigate to Extensions > Manage Extensions.
- In the Manage Extensions window's search box, search for "SQL Server Integration Services Projects 2022" and select the extension in the list.
- Click Download.
- Close Visual Studio and run the downloaded Microsoft.DataTools.IntegrationServices.exe installer. Proceed through the installer with default settings.
- Open Visual Studio. There should now be an "Integration Services Project" project template available.
Adding the Epicor Kinetic Connection Manager
Create a new connection manager as follows:
- Create a Visual Studio project with the "Integration Services Project" template.
- In the project, right-click within the Connection Managers window and select New Connection from the menu.
- In the Description column, select CData Epicor Kinetic Connection Manager and click Add...
- Configure the component as described in the next section.
Alternatively, if you have an existing project and CData Epicor Kinetic Source or CData Epicor Kinetic Destination:
- Right-click your CData Epicor Kinetic source or destination component in your data flow
- Select Edit... to open an editor window.
- Click the New... button next to the Connection manager: dropdown selector to create a connection manager.
- Configure the component as described in the next section.
Connecting to Epicor Kinetic
To successfully connect to your ERP instance, you must specify the following connection properties:- Url, set this to the url of the server hosting your ERP instance. For example, https://myserver.EpicorSaaS.com
- ERPInstance, set this to the name of your ERP instance.
- User, set this to the username of your account.
- Password, set this to the password of your account.
- Service, set this to the service you want to retrieve data from. For example, BaqSvc.
In addition, you may also set the optional connection properties:
- ApiKey, An optional key that may be required for connection to some services depending on your account configuration.
- ApiVersion, Defaults to v1. May be set to v2 to use the newer Epicor API.
- Company, Required if you set the ApiVersion to v2.
Authenticating to Epicor Kinetic
OpenID with AzureAD
OpenID Connect with Azure AD is a connection type that goes through OAuth. Set the AuthScheme to AzureADOpenID. The following sections assume that you have done so.Desktop Applications
Follow the steps below to authenticate with the credentials for a custom OAuth app. See Creating an Azure AD Application. Get an OAuth Access Token
You are ready to connect after setting one of the below connection properties groups depending on the authentication type.
- Authenticating using a Client Secret
- OAuthClientId: Set this to the Client Id in your app settings.
- OAuthClientSecret: Set this to the Client Secret in your app settings.
- CallbackURL: Set this to the Redirect URL in your app settings.
- InitiateOAuth: Set this to GETANDREFRESH. You can use InitiateOAuth to avoid repeating the OAuth exchange and manually setting the OAuthAccessToken. .
- Authenticating using a Certificate
- OAuthClientId: Set this to the Client Id in your app settings.
- OAuthJWTCert: Set this to the JWT Certificate store.
- OAuthJWTCertType: Set this to the type of the certificate store specified by OAuthJWTCert.
- CallbackURL: Set this to the Redirect URL in your app settings.
- InitiateOAuth: Set this to GETANDREFRESH. You can use InitiateOAuth to avoid repeating the OAuth exchange and manually setting the OAuthAccessToken. .
When you connect the component opens the OAuth endpoint in your default browser. Log in and grant permissions to the application. The component then completes the OAuth process:
- Extracts the access token from the callback URL and authenticates requests.
- Obtains a new access token when the old one expires.
- Saves OAuth values in OAuthSettingsLocation to be persisted across connections.
Headless Machines
To configure the driver to use OAuth with a user account on a headless machine, you need to authenticate on another device that has an internet browser.
- Choose one of these two options:
- Option 1: Obtain the OAuthVerifier value as described in "Obtain and Exchange a Verifier Code" below.
- Option 2: Install the component on another machine and transfer the OAuth authentication values after you authenticate through the usual browser-based flow, as described in "Transfer OAuth Settings" below.
- Then configure the component to automatically refresh the access token from the headless machine.
Option 1: Obtain and Exchange a Verifier Code
To obtain a verifier code, you must authenticate at the OAuth authorization URL.
Follow the steps below to authenticate from the machine with an internet browser and obtain the OAuthVerifier connection property.
- Choose one of these options:
- If you are using the Embedded OAuth Application click Epicor Kinetic OAuth endpoint to open the endpoint in your browser.
- If you are using a custom OAuth application, create the Authorization URL by setting the following properties:
- InitiateOAuth: Set to OFF.
- OAuthClientId: Set to the client Id assigned when you registered your application.
- OAuthClientSecret: Set to the client secret assigned when you registered your application.
- Log in and grant permissions to the component. You are then redirected to the callback URL, which contains the verifier code.
- Save the value of the verifier code. Later you will set this in the OAuthVerifier connection property.
On the headless machine, set the following connection properties to obtain the OAuth authentication values:
- InitiateOAuth: Set this to REFRESH.
- OAuthVerifier: Set this to the verifier code.
- OAuthClientId: (custom applications only) Set this to the client Id in your custom OAuth application settings.
- OAuthClientSecret: (custom applications only) Set this to the client secret in the custom OAuth application settings.
- OAuthSettingsLocation: Set this to the location of the file where the driver saves the OAuth token values that persist across connections.
After the OAuth settings file is generated, you need to re-set the following properties to connect:
- InitiateOAuth: Set this to REFRESH.
- OAuthClientId: (custom applications only) Set this to the client Id assigned when you registered your application.
- OAuthClientSecret: (custom applications only) Set this to the client secret assigned when you registered your application.
- OAuthSettingsLocation: Set this to the location containing the encrypted OAuth authentication values. Make sure this location grants read and write permissions to the component to enable the automatic refreshing of the access token.
Option 2: Transfer OAuth Settings
Prior to connecting on a headless machine, you need to create and install a connection with the driver on a device that supports an internet browser. Set the connection properties as described in "Desktop Applications" above.
After completing the instructions in "Desktop Applications", the resulting authentication values are encrypted and written to the location specified by OAuthSettingsLocation. The default filename is OAuthSettings.txt.
Once you have successfully tested the connection, copy the OAuth settings file to your headless machine.
On the headless machine, set the following connection properties to connect to data:
- InitiateOAuth: Set this to REFRESH.
- OAuthClientId: (custom applications only) Set this to the client Id assigned when you registered your application.
- OAuthClientSecret: (custom applications only) Set this to the client secret assigned when you registered your application.
- OAuthSettingsLocation: Set this to the location of your OAuth settings file. Make sure this location gives read and write permissions to the component to enable the automatic refreshing of the access token.