ODBC Driver for Twitter

Build 23.0.8839

Windows DSN Configuration

Using the Microsoft ODBC Data Source Administrator

You can use the Microsoft ODBC Data Source Administrator to edit the DSN configuration. Note that the DSN is created during the installation process.

Complete the following steps to edit the DSN configuration:

  1. Select Start > Search, and enter ODBC Data Sources in the Search box.
  2. Choose the version of the ODBC Administrator that corresponds to the bitness of your application (32-bit or 64-bit).
  3. Click the System DSN tab.
  4. Select the system data source and click Configure.
  5. Edit the information on the Connection tab and click OK.

Note: For .NET Framework 4.0, the driver distributes Microsoft Visual C++ 2015-2022 Redistributable. For .NET Framework 3.5, the driver distributes Microsoft Visual C++ 2008 Redistributable.

Ensuring Registry Access

The driver stores connection information in the Windows registry. To ensure that the driver can write to the registry, perform either of the following actions:

  1. Run the calling application as an administrator.
  2. Connect via a User DSN instead of a System DSN.

Connecting to Twitter (OAuth)

NOTE: Which version of OAuth you use depends on the table or view you want to access. For the StreamRules table and the TweetStream view, you must use OAuth 2.0 App-Only. For all other tables and views, use OAuth 1.1.

OAuth 2.0 App-Only (Bearer Token)

To establish a connection for the StreamRules table or the TweetStream view, you need to authenticate using OAuth 2.0 App-Only authentication.

First, generate a bearer token from Twitter's website. The YourBearerToken value is generated from: Twitter's Developer Portal > ProjectOfInterest > Keys and Tokens. For more information, see the Twitter Developers Portal Documentation.

After generating the token and setting the following, you are ready to connect:

  • InitiateOAuth: Set this to OFF
  • OAuthAccessToken: Set this to YourBearerToken's value.

If you want to access any other tables and views (besides StreamRules and TweetStream), follow the OAuth 1.1 procedures described below.

OAuth 1.1

Desktop Applications

You can connect without setting any connection properties for your user credentials. Or you can create a custom OAuth application. See Creating a Custom OAuth App for more information about custom OAuth applications.

The only difference between the two is that you must set additional connection properties if you choose to use a custom application.

After setting the following, you are ready to connect:

  • OAuthClientId (custom applications only): Set this to the consumer key in your app settings.
  • OAuthClientSecret (custom applications only): Set this to the consumer secret in your app settings.
When you connect the driver opens the OAuth endpoint in your default browser. Log in and grant permissions to the application. The driver then completes the OAuth process.

Headless Machines

To configure the driver to use OAuth with a user account on a headless machine, you need to authenticate on another device that has an internet browser.

  1. Choose one of two options:
    • Option 1: Obtain the OAuthVerifier value as described in "Obtain and Exchange a Verifier Code" below.
    • Option 2: Install the driver on a machine with an internet browser and transfer the OAuth authentication values after you authenticate through the usual browser-based flow, as described in "Transfer OAuth Settings" below.
  2. Then configure the driver to automatically refresh the access token on the headless machine.

Option 1: Obtain and Exchange a Verifier Code

To obtain a verifier code, you must authenticate at the OAuth authorization URL.

Follow the steps below to authenticate from the machine with an internet browser and obtain the OAuthVerifier connection property.

  1. Choose one of these options:
    • If you are using the Embedded OAuth Application, call the GetOAuthAuthorizationURL stored procedure. Open the URL returned by the stored procedure in a browser.
    • If you are using a custom OAuth application, set the following properties:
      • InitiateOAuth: Set to OFF.
      • OAuthClientId: Set this to the Client Id in your app settings.
      • OAuthClientSecret: Set this to the Client Secret in your app settings.
      Then call the GetOAuthAuthorizationURL stored procedure with the CallbackURL input parameter set to the exact Redirect URI you specified in your app settings. Open the URL returned by the stored procedure in a browser.
  2. Log in and grant permissions to the driver. You are then redirected to the callback URL, which contains the verifier code. Save the value of the verifier code. Later you will set this in the OAuthVerifier connection property.
Next, you need to exchange the OAuth verifier code for OAuth refresh and access tokens.

On the headless machine, set the following connection properties to obtain the OAuth authentication values:

  • InitiateOAuth: Set this to REFRESH.
  • OAuthVerifier: Set this to the noted verifier code (the value of the code parameter in the redirect URI).
  • OAuthClientId: (custom applications only) Set this to the noted App key value from your OAuth app settings.
  • OAuthClientSecret: (custom applications only) Set this to the App secret from your OAuth app settings.
  • AuthToken: Set to the authentication token returned by the GetOAuthAuthorizationURL stored procedure.
  • AuthKey: Set to the authentication key returned by the GetOAuthAuthorizationURL stored procedure.
  • OAuthSettingsLocation: Set this to persist the encrypted OAuth authentication values to the specified location.

Test the connection to generate the OAuth settings file, then re-set the following properties to connect:

  • InitiateOAuth: Set this to REFRESH.
  • OAuthClientId: (custom applications only) Set this to the noted App key value from your OAuth app settings.
  • OAuthClientSecret: (custom applications only) Set this to the App secret from your OAuth app settings.
  • OAuthSettingsLocation: Set this to the location containing the encrypted OAuth authentication values. Make sure this location gives read and write permissions to the driver to enable the automatic refreshing of the access token.

Option 2: Transfer OAuth Settings

Prior to connecting on a headless machine, you need to install and create a connection with the driver on a device that supports an internet browser. Set the connection properties as described in "Desktop Applications" above.

After completing the instructions in "Desktop Applications", the resulting authentication values are encrypted and written to the location specified by OAuthSettingsLocation. The default filename is OAuthSettings.txt.

Test the connection to generate the OAuth settings file, then copy the OAuth settings file to your headless machine.

On the headless machine, set the following connection properties to connect to data:

  • InitiateOAuth: Set this to REFRESH.
  • OAuthClientId: (custom applications only) Set this to the noted App key value from your OAuth app settings.
  • OAuthClientSecret: (custom applications only) Set this to the App secret from your OAuth app settings.
  • OAuthSettingsLocation: Set this to the location of the OAuth settings file you copied from the machine with the browser. Make sure this location gives read and write permissions to the driver to enable the automatic refreshing of the access token.

Copyright (c) 2024 CData Software, Inc. - All rights reserved.
Build 23.0.8839