FireDAC Components for Act-On

Build 23.0.8839

Establishing a Connection

You can create and manage connections with the Data Explorer and the FireDAC Connection Editor wizards. See Connection Definitions for more information on creating connections from code and creating persistent, private, or temporary connections.

Authenticating to Act-On

Act-On uses the OAuth authentication standard. To authenticate using OAuth, you will need to create an app to obtain the OAuthClientId, OAuthClientSecret, and CallbackURL connection properties.

Desktop Applications

CData provides an embedded OAuth application that simplifies OAuth desktop Authentication. Alternatively, you can create a custom application. See Creating a Custom OAuth App for information on creating custom applications and reasons for doing so.

For authentication, the only difference between the two methods is that you must set two additional connection properties when using custom OAuth applications.

After setting the following connection properties, you are ready to connect:

  • InitiateOAuth: Set this to GETANDREFRESH. You can use InitiateOAuth to avoid repeating the OAuth exchange and manually setting the OAuthAccessToken.
  • OAuthClientId: (custom applications only) Set to the Client ID in your application settings.
  • OAuthClientSecret: (custom applications only) Set to the Client Secret in your application settings.

When you connect, the component opens the OAuth endpoint in your default browser. Log in and grant permissions to the application. The component then completes the OAuth process as follows:

  • Extracts the access token from the callback URL.
  • Obtains a new access token when the old one expires.
  • Saves OAuth values in OAuthSettingsLocation that persist across connections.

Web Applications

When connecting via a web application, you need to register a custom OAuth application with Act-On. See Creating a Custom OAuth App for more information. You can then use the driver to get and manage the OAuth token values.

First, get an OAuthAccessToken by setting the following connection properties:

  • OAuthClientId: Set to the client Id in your application settings.
  • OAuthClientSecret: Set to the client secret in your application settings.

Then call stored procedures to complete the OAuth exchange:

  1. Call the GetOAuthAuthorizationURL stored procedure. Set the CallbackURL input to the callback URL you specified in your application settings. If necessary, set the Scope parameter to request custom permissions. The stored procedure returns the URL of the OAuth endpoint.
  2. Open the URL, log in, and authorize the application. You are redirected back to the callback URL.
  3. Call the GetOAuthAccessToken stored procedure. Set the AuthMode input to WEB. Set the Verifier input to the "code" parameter in the query string of the callback URL. If necessary, set the Scope parameter to request custom permissions.

After you have obtained the access and refresh tokens, you can connect to data and refresh the OAuth access token either automatically or manually.

Automatic Refresh of the OAuth Access Token

To have the driver automatically refresh the OAuth access token, set the following on the first data connection:

  • InitiateOAuth: Set this to REFRESH.
  • OAuthClientId: Set this to the client Id in your application settings.
  • OAuthClientSecret: Set this to the client secret in your application settings.
  • OAuthAccessToken: Set this to the access token returned by GetOAuthAccessToken.
  • OAuthRefreshToken: Set this to the refresh token returned by GetOAuthAccessToken.
  • OAuthSettingsLocation: Set this to the location where the component saves the OAuth token values, which persist across connections.
On subsequent data connections, the values for OAuthAccessToken and OAuthRefreshToken are taken from OAuthSettingsLocation.

Manual Refresh of the OAuth Access Token

The only value needed to manually refresh the OAuth access token when connecting to data is the OAuth refresh token.

Use the RefreshOAuthAccessToken stored procedure to manually refresh the OAuthAccessToken after the ExpiresIn parameter value returned by GetOAuthAccessToken has elapsed, then set the following connection properties:

  • OAuthClientId: Set this to the client Id in your application settings.
  • OAuthClientSecret: Set this to the client secret in your application settings.

Then call RefreshOAuthAccessToken with OAuthRefreshToken set to the OAuth refresh token returned by GetOAuthAccessToken. After the new tokens have been retrieved, open a new connection by setting the OAuthAccessToken property to the value returned by RefreshOAuthAccessToken.

Finally, store the OAuth refresh token so that you can use it to manually refresh the OAuth access token after it has expired.

Headless Machines

To configure the driver to use OAuth with a user account on a headless machine, you need to authenticate on another device that has an internet browser.

  1. Choose one of two options:

    • Option 1: Obtain the OAuthVerifier value as described in "Obtain and Exchange a Verifier Code" below.
    • Option 2: Install the component on a machine with a browser and transfer the OAuth authentication values after you authenticate through the usual browser-based flow, as described in "Transfer OAuth Settings" below.

  2. Then configure the component to automatically refresh the access token on the headless machine.

Option 1: Obtain and Exchange a Verifier Code

To obtain a verifier code, you must authenticate at the OAuth authorization URL.

Follow the steps below to authenticate from the machine with an internet browser and obtain the OAuthVerifier connection property.

  1. Choose one of these options:

    • If you are using the Embedded OAuth Application click Act-On OAuth endpoint to open the endpoint in your browser.
    • If you are using a Custom OAuthd Application, create the Authorization URL by setting the following properties:
      • InitiateOAuth: Set to OFF.
      • OAuthClientId: Set to the client Id assigned when you registered your application.
      • OAuthClientSecret: Set to the client secret assigned when you registered your application.
      Then call the GetOAuthAuthorizationURL stored procedure with the appropriate CallbackURL. Open the URL returned by the stored procedure in a browser.

  2. Log in and grant permissions to the component. You are then redirected to the callback URL, which contains the verifier code.
  3. Save the value of the verifier code. Later you will set this in the OAuthVerifier connection property.
Next, you need to exchange the OAuth verifier code for OAuth refresh and access tokens. Set the following properties:

On the headless machine, set the following connection properties to obtain the OAuth authentication values.

  • InitiateOAuth: Set this to REFRESH.
  • OAuthVerifier: Set this to the verifier code.
  • OAuthClientId: (custom applications only) Set this to the client Id in your custom OAuth application settings.
  • OAuthClientSecret: (custom applications only) Set this to the client secret in the custom OAuth application settings.
  • OAuthSettingsLocation: Set this to persist the encrypted OAuth authentication values to the specified location.

After the OAuth settings file is generated, you need to re-set the following properties to connect:

  • InitiateOAuth: Set this to REFRESH.
  • OAuthClientId: (custom applications only) Set this to the client Id assigned when you registered your application.
  • OAuthClientSecret: (custom applications only) Set this to the client secret assigned when you registered your application.
  • OAuthSettingsLocation: Set this to the location containing the encrypted OAuth authentication values. Make sure this location gives read and write permissions to the component to enable the automatic refreshing of the access token.

Option 2: Transfer OAuth Settings

Prior to connecting on a headless machine, you need to install and create a connection with the driver on a device that supports an internet browser. Set the connection properties as described in "Desktop Applications" above.

After completing the instructions in "Desktop Applications", the resulting authentication values are encrypted and written to the location specified by OAuthSettingsLocation. The default filename is OAuthSettings.txt.

After you have successfully tested the connection, copy the OAuth settings file to your headless machine.

On the headless machine, set the following connection properties to connect to data:

  • InitiateOAuth: Set this to REFRESH.
  • OAuthClientId: (custom applications only) Set this to the client Id assigned when you registered your application.
  • OAuthClientSecret: (custom applications only) Set this to the client secret assigned when you registered your application.
  • OAuthSettingsLocation: Set this to the location of your OAuth settings file. Make sure this location gives read and write permissions to the component to enable the automatic refreshing of the access token.

Using the FireDAC Connection Editor

Complete the following steps to use the FireDAC Connection Editor to assign a Act-On connection to a TFDConnection object:

  1. Open a project and drop a TFDPhysCDataActOnDriverLink from the Tool Palette onto the Form Designer.
  2. Drop a TFDConnection object onto the Form Designer.
  3. Double-click the TFDConnection and select CDataActOn in the Driver Id menu.
  4. Define the necessary connection properties.
  5. To execute ad-hoc SQL statements based on this connection, enter SQL commands on the SQL Script tab.
  6. In the Form Designer, select the TFDConnection object and set the Connected property to true.

Using the Data Explorer

Complete the following steps to use the Data Explorer to define persistent connections that can be shared across applications and projects:

  1. Click View > Tool Windows > Data Explorer in RAD Studio and expand the FireDAC node.
  2. Right-click the CData Act-On Data Source node and click Add New Connection.
  3. Enter a name for the connection. The FireDAC Connection Editor opens.

Working with Persistent Connections

The connections you define in the Data Explorer can be assigned to a TFDConnection object by specifying the connection name in the TFDConnection object's ConnectionDefName property.

Browsing Data and Metadata

The Data Explorer also provides options for browsing Act-On objects at design time:

  • Expand the CData Act-On Data Source node in the Data Explorer to view the defined connections.
  • Expand a connection node to find the database objects available for a connection.
  • Drill down to a database object to find metadata such as primary keys.
  • To display data, double-click a table or view or right-click and click View.

Copyright (c) 2024 CData Software, Inc. - All rights reserved.
Build 23.0.8839