Power BI Connector for Monday

Build 24.0.9060

Creating the Data Source Name

This section describes how to edit the DSN configuration and then authenticate and connect to Monday APIs.

DSN Configuration

You can use the Microsoft ODBC Data Source Administrator to edit the DSN configuration. Note that the installation process creates a both a user DSN and a system DSN, as described in Installing the Connector.

Note: The connector stores connection information in the Windows registry. To ensure that the connector can write to the registry, either run Power BI as an administrator or use a User DSN for your connection instead of a System DSN.

User DSN

Complete the following steps to edit the DSN configuration:

  1. Select Start > Search, and enter ODBC Data Sources in the Search box.
  2. Choose the version of the ODBC Administrator that corresponds to the bitness of your Power BI Desktop installation (32-bit or 64-bit).
  3. Select the system data source and click Configure.
  4. Edit the information on the Connection tab and click OK.

System DSN

Configure the system DSN the same way as the user DSN, except you will need to switch to the System DSN tab before performing Step 3.

If you're using Power BI's On-Premises Data Gateway with Standard mode, you must use the system DSN.

You must also specify a valid location for OAuthSettingsLocation (a path where OAuth credentials are locally stored to avoid repeated OAuth prompts).

This is because the Standard mode runs on service mode and can only access permitted locations, such as C:\Windows\ServiceProfiles\PBIEgwService\AppData\Local\Microsoft\On-premises data gateway.

Connecting to Monday

Monday AuditLog API

Monday AuditLog API only supports authentication via API Token.

To generate the audit log API token:

  1. Log into your Monday account.
  2. Access the Admin section.
  3. Navigate to Security.
  4. Click the Audit tab.
  5. Click Monitor by API. Monday displays the API token.

After you retrieve the API token, set the following conenction properties:

  • Schema=AuditLog
  • AuthScheme=Token
  • APIToken=The audit log API token you just obtained
  • Domain=https://yourdomain.monday.com

You are now ready to connect to Monday AuditLog API.

Monday GraphQL API

Monday GraphQL API supports authentication via either API Token or the OAuth standard.

API Token

To connect to connector via an API Token, set the AuthScheme to Token and obtain the APIToken as follows:

  1. Log in to your Monday account.
  2. Navigate to Manage Applications in the left pane. Monday displays a list of application to manage.
  3. Select the application that you would like to create a token for. You may need to create an application first.
  4. To generate an APIToken, click Create token.

OAuth

Monday supports OAuth authentication only. To enable this authentication from all OAuth flows, you must set AuthScheme to OAuth, and you must create a custom OAuth application.

The following subsections describe how to authenticate to Monday from three common authentication flows:

  • Desktop: a connection to a server on the user's local machine, frequently used for testing and prototyping.
  • Web: access to data via a shared website.
  • Headless Server: a dedicated computer that provides services to other computers and their users, which is configured to operate without a monitor and keyboard.

For information about how to create a custom OAuth application, see Creating a Custom OAuth Application.

For a complete list of connection string properties available in Monday, see Connection.

Desktop Applications

To authenticate with the credentials for a custom OAuth application, you must get and refresh the OAuth access token. After you do that, you are ready to connect.

Get and refresh the OAuth access token:

  • InitiateOAuth = GETANDREFRESH. Used to automatically get and refresh the OAuthAccessToken.
  • OAuthClientId = the client Id assigned when you registered your application.
  • OAuthClientSecret = the client secret that was assigned when you registered your application.
  • CallbackURL = the redirect URI that was defined when you registered your application.

When you connect, the connector opens Monday's OAuth endpoint in your default browser. Log in and grant permissions to the application.

After you grant permissions to the application, the connector then completes the OAuth process:

  1. The connector obtains an access token from Monday and uses it to request data.
  2. The OAuth values are saved in the path specified in OAuthSettingsLocation. These values persist across connections.

When the access token expires, the connector refreshes it automatically.

Automatic refresh of the OAuth access token:

To have the connector automatically refresh the OAuth access token, do the following:

  1. The first time you connect to data, set the following connection parameters:
    • InitiateOAuth = REFRESH.
    • OAuthClientId = the client Id in your application settings.
    • OAuthClientSecret = the client secret in your application settings.
    • OAuthAccessToken = the access token returned by .
    • OAuthSettingsLocation = the path where you want the connector to save the OAuth values, which persist across connections.
  2. On subsequent data connections, set the following:
    • InitiateOAuth
    • OAuthSettingsLocation

Headless Machines

If you need to log in to a resource that resides on a headless machine, you must authenticate on another device that has an internet browser. You can do this in either of the following ways:

  • Option 1: Obtain the OAuthVerifier value.
  • Option 2: Install the connector on a machine with an internet browser and transfer the OAuth authentication values after you authenticate through the usual browser-based flow.

After you execute either Option 1 or Option 2, configure the driver to automatically refresh the access token on the headless machine.

Option 1: Obtaining and Exchanging a Verifier Code

To obtain a verifier code, you must authenticate at the OAuth authorization URL. Do the following:

  1. Authenticate from the machine with an internet browser, and obtain the OAuthVerifier connection property.

    Set the following properties:

    • InitiateOAuth = OFF.
    • OAuthClientId = the client Id assigned when you registered your application.
    • OAuthClientSecret = the client secret assigned when you registered your application.

  2. Call the GetOAuthAuthorizationURL stored procedure. The stored procedure returns the CallbackURL established when the custom OAuth application was registered. (See Creating a Custom OAuth Application.)

    Copy this URL and paste it into a new browser tab.

  3. Log in and grant permissions to the connector. The OAuth application redirects you the redirect URI, with a parameter called code appended. Note the value of this parameter; you will need it later, to configure the OAuthVerifier connection property.

  4. Exchange the OAuth verifier code for OAuth refresh and access tokens. On the headless machine, set the following connection properties to obtain the OAuth authentication values:

    • InitiateOAuth = REFRESH.
    • OAuthVerifier = the noted verifier code (the value of the code parameter in the redirect URI).
    • OAuthSettingsLocation = persist the encrypted OAuth authentication values to the specified file.
    • OAuthClientId = the client Id in your custom OAuth application settings.
    • OAuthClientSecret = the client secret in the custom OAuth application settings.

  5. Test the connection to generate the OAuth settings file.

  6. After you re-set the following properties, you are ready to connect:

    • InitiateOAuth = REFRESH.
    • OAuthSettingsLocation = the file containing the encrypted OAuth authentication values. To enable the automatic refreshing of the access token, be sure that this file gives read and write permissions to the connector.
    • OAuthClientId = the client Id assigned when you registered your application.
    • OAuthClientSecret = the client secret assigned when you registered your application.

Option 2: Transferring OAuth Settings

Prior to connecting on a headless machine, you must install and create a connection with the driver on a device that supports an internet browser. Set the connection properties as described above in "Desktop Applications".

After completing the instructions in "Desktop Applications", the resulting authentication values are encrypted and written to the path specified by OAuthSettingsLocation. The default filename is OAuthSettings.txt.

Test the connection to generate the OAuth settings file, then copy the OAuth settings file to your headless machine.

To connect to data via the headless machine, set the following connection properties:

  • InitiateOAuth = REFRESH
  • OAuthSettingsLocation = the path to the OAuth settings file you copied from the machine with the browser. To enable automatic refreshing of the access token, ensure that this file gives read and write permissions to the connector.
  • OAuthClientId = the client Id assigned when you registered your custom OAuth application.
  • OAuthClientSecret = the client secret assigned when you registered your custom OAuth application.

Copyright (c) 2024 CData Software, Inc. - All rights reserved.
Build 24.0.9060