TDV Adapter for XML

Build 24.0.9060

Connecting to Box

Connecting to Box

Use the OAuth authentication standard to connect to Box. You can authenticate with a user account or with a service account. A service account is required to grant organization-wide access scopes to the adapter. The adapter facilitates these authentication flows as described below.

User Accounts (OAuth)

AuthScheme must be set to OAuth in all user account flows.

Desktop Applications

CData provides an embedded OAuth application that simplifies OAuth desktop Authentication. Alternatively, you can create a custom OAuth application. See Create a Custom OAuth App for information about creating custom applications and reasons for doing so.

Get and Refresh the OAuth Access Token

After setting the following, you are ready to connect:

  • InitiateOAuth: Set this to GETANDREFRESH. You can use InitiateOAuth to avoid repeating the OAuth exchange and manually setting the OAuthAccessToken.
  • OAuthClientId (custom applications only): Set this to the client Id assigned when you registered your app.
  • OAuthClientSecret (custom applications only): Set this to the client secret assigned when you registered your app.
  • CallbackURL (custom application only): Set this to the redirect URI defined when you registered your app. For example: http://localhost:33333
When you connect, the adapter opens Box's OAuth endpoint in your default browser. Log in and grant permissions to the application. The adapter then completes the OAuth process:
  1. The adapter obtains an access token from Box and uses it to request data.
  2. The OAuth values are saved in the location specified in OAuthSettingsLocation, to be persisted across connections.
The adapter refreshes the access token automatically when it expires.

Web Applications

When connecting via a Web application, you need to register a custom OAuth app with Box. You can then use the adapter to get and manage the OAuth token values. See Create a Custom OAuth App for more information.

Get an OAuth Access Token

Set the following connection properties to obtain the OAuthAccessToken:

  • OAuthClientId: Set this to the client Id in your app settings.
  • OAuthClientSecret: Set this to the client secret in your app settings.

Then call stored procedures to complete the OAuth exchange:

  1. Call the GetOAuthAuthorizationURL stored procedure. Set the CallbackURL input to the Redirect URI you specified in your app settings. The stored procedure returns the URL to the OAuth endpoint.

  2. Navigate to the URL that the stored procedure returned in Step 1. Log in, and authorize the web application. After authenticating, the browser redirects you to the redirect URI. There will be a parameter called code appended to the redirect URI. Note the value of this parameter.
  3. Call the GetOAuthAccessToken stored procedure. Set the AuthMode input to WEB. Set the Verifier input to the code parameter in the query string of the redirect URI.

After you have obtained the access and refresh tokens, you can connect to data and refresh the OAuth access token either automatically or manually.

Automatic Refresh of the OAuth Access Token

To have the adapter automatically refresh the OAuth access token, set the following on the first data connection.

  • InitiateOAuth: Set this to REFRESH.
  • OAuthClientId: Set this to the client Id in your app settings.
  • OAuthClientSecret: Set this to the client secret in your app settings.
  • OAuthAccessToken: Set this to the access token returned by GetOAuthAccessToken.
  • OAuthRefreshToken: Set this to the refresh token returned by GetOAuthAccessToken.
  • OAuthSettingsLocation: Set this to the location where you want the adapter to save the OAuth values, which persist across connections.

Manual Refresh of the OAuth Access Token

The only value needed to manually refresh the OAuth access token when connecting to data is the OAuth refresh token. Use the RefreshOAuthAccessToken stored procedure to manually refresh the OAuthAccessToken after the ExpiresIn parameter value returned by GetOAuthAccessToken has elapsed, then set the following connection properties:

  • OAuthClientId: Set this to the client Id in your app settings.
  • OAuthClientSecret: Set this to the client secret in your app settings.

Then call RefreshOAuthAccessToken with OAuthRefreshToken set to the OAuth refresh token returned by GetOAuthAccessToken. After the new tokens have been retrieved, open a new connection by setting the OAuthAccessToken property to the value returned by RefreshOAuthAccessToken.

Finally, store the OAuth refresh token so that you can use it to manually refresh the OAuth access token after it has expired.

Headless Machines

To configure the driver, use OAuth with a user account on a headless machine. You need to authenticate on another device that has an internet browser.

  1. Choose one of two options:
    • Option 1: Obtain the OAuthVerifier value as described in "Obtain and Exchange a Verifier Code" below.
    • Option 2: Install the adapter on a machine with an internet browser and transfer the OAuth authentication values after you authenticate through the usual browser-based flow.
  2. Then configure the adapter to automatically refresh the access token on the headless machine.

Option 1: Obtain and Exchange a Verifier Code

To obtain a verifier code, you must authenticate at the OAuth authorization URL.

Follow the steps below to authenticate from the machine with an internet browser and obtain the OAuthVerifier connection property.

  1. Choose one of these options:
    • If you are using the Embedded OAuth Application, call the GetOAuthAuthorizationURL stored procedure. Open the URL returned by the stored procedure in a browser.
    • If you are using a custom OAuth application, set the following properties:
      • InitiateOAuth: Set to OFF.
      • OAuthClientId: Set to the client Id assigned when you registered your application.
      • OAuthClientSecret: Set to the client secret assigned when you registered your application.
      Then call the GetOAuthAuthorizationURL stored procedure with the appropriate CallbackURL. Open the URL returned by the stored procedure in a browser.
  2. Log in and grant permissions to the adapter. You are then redirected to the redirect URI. There will be a parameter called code appended to the redirect URI. Note the value of this parameter. Later you will set this in the OAuthVerifier connection property.
Next, you need to exchange the OAuth verifier code for OAuth refresh and access tokens.

On the headless machine, set the following connection properties to obtain the OAuth authentication values:

  • InitiateOAuth: Set this to REFRESH.
  • OAuthVerifier: Set this to the noted verifier code (the value of the code parameter in the redirect URI).
  • OAuthClientId: (custom applications only) Set this to the client Id in your custom OAuth application settings.
  • OAuthClientSecret: (custom applications only) Set this to the client secret in the custom OAuth application settings.
  • OAuthSettingsLocation: Set this to persist the encrypted OAuth authentication values to the specified location.

Test the connection to generate the OAuth settings file, then re-set the following properties to connect:

  • InitiateOAuth: Set this to REFRESH.
  • OAuthClientId: (custom applications only) Set this to the client Id assigned when you registered your application.
  • OAuthClientSecret: (custom applications only) Set this to the client secret assigned when you registered your application.
  • OAuthSettingsLocation: Set this to the location containing the encrypted OAuth authentication values. Make sure this location gives read and write permissions to the adapter to enable the automatic refreshing of the access token.

Option 2: Transfer OAuth Settings

Prior to connecting on a headless machine, you need to install and create a connection with the driver on a device that supports an internet browser. Set the connection properties as described in "Desktop Applications" above.

After completing the instructions in "Desktop Applications", the resulting authentication values are encrypted and written to the location specified by OAuthSettingsLocation. The default filename is OAuthSettings.txt.

Test the connection to generate the OAuth settings file, then copy the OAuth settings file to your headless machine.

On the headless machine, set the following connection properties to connect to data:

  • InitiateOAuth: Set this to REFRESH.
  • OAuthClientId: (custom applications only) Set this to the client Id assigned when you registered your application.
  • OAuthClientSecret: (custom applications only) Set this to the client secret assigned when you registered your application.
  • OAuthSettingsLocation: Set this to the location of the OAuth settings file you copied from the machine with the browser. Make sure this location gives read and write permissions to the adapter to enable the automatic refreshing of the access token.

Authenticate with a Service Account

Set the AuthScheme to OAuthJWT to authenticate with this method.

Service accounts have silent authentication, without user authentication in the browser. You can also use a service account to delegate enterprise-wide access scopes to the adapter.

You need to create an OAuth application in this flow. See Create a Custom OAuth App to create and authorize an app. You can then connect to Box data that the service account has permission to access.

After setting the following connection properties, you are ready to connect:

  • InitiateOAuth: Set to GETANDREFRESH.
  • OAuthClientId: Set to the Client Id in your app settings.
  • OAuthClientSecret: Set to the Client Secret in your app settings.
  • OAuthJWTCertType: Set to "PEMKEY_FILE".
  • OAuthJWTCert: Set to the path to the .pem file you generated.
  • OAuthJWTCertPassword: Set to the password of the .pem file.
  • OAuthJWTCertSubject: Set to "*" to pick the first certificate in the certificate store.
  • OAuthJWTSubjectType: Set to "enterprise" or "user" depending on the Application Access Value you selected in your app settings. The default value of this connection property is "enterprise".
  • OAuthJWTSubject: Set to your enterprise Id if your subject type is set to "enterprise" or your app user Id if your subject type is set to "user".
  • OAuthJWTPublicKeyId: Set to the Id of your public key in your app settings.
When you connect the adapter completes the OAuth flow for a service account.
  1. Creates and signs the JWT with the claim set required by the adapter.
  2. Exchanges the JWT for the access token.
  3. Saves OAuth values in OAuthSettingsLocation to be persisted across connections.
  4. Submits the JWT for a new access token when the token expires.

Copyright (c) 2024 CData Software, Inc. - All rights reserved.
Build 24.0.9060