Tableau Connector for Oracle Eloqua

Build 25.0.9434

Miscellaneous

This section provides a complete list of the Miscellaneous properties you can configure in the connection string for this provider.


PropertyDescription
BatchSizeSpecifies the maximum number of rows included in each batch submitted during batch operations. To submit the entire batch as a single request, set BatchSize to 0 .
BulkPollingIntervalThe time interval between requests that check the availability of the bulk query response. The default value is 200 ms.
BulkQueryTimeoutThe timeout in minutes for which the provider will wait for a bulk query response. The default value is 25 minutes.
ConnectionLifeTimeSpecifies the maximum lifetime of a connection in seconds. When the specified time elapses, the provider closes the connection.
ConnectOnOpenSpecifies whether the provider establishes a connection to Oracle Eloqua immediately upon opening the connection. Set ConnectOnOpen to True if immediate connectivity verification is necessary.
DataRetentionDurationThe length of time (in hours) that bulk data is stored on the server. Valid values are from 1 hour to 2 weeks. The default value is 24 hours.
DisplayColumnNameSpecifies the display name for columns when using the Oracle Eloqua Bulk API. The possible settings are empty string, 'internal', and 'statement'.
MapDataCardsCaseSensitiveMatchWhether or not to use case sensitive match in data card mapping.
MapDataCardsRelationshipComma-separated list of the relationships between the Custom Object tables and the Entity tables.
MaxRowsSpecifies the maximum number of rows returned for queries that do not include either aggregation or GROUP BY.
OtherSpecifies additional hidden properties for specific use cases., to be used only when our Support team advises it, to address specific issues. See Remarks for details.
PagesizeSpecifies the maximum number of records per page the provider returns when requesting data from Oracle Eloqua.
PoolIdleTimeoutSpecifies the maximum idle time, in seconds, that a connection can remain in the pool before being closed. Requires UseConnectionPooling=True.
PoolMaxSizeSpecifies the maximum number of connections allowed in the connection pool.
PoolMinSizeSpecifies the minimum number of connections to be maintained in the connection pool at all times.
PoolWaitTimeSpecifies the maximum number of seconds a connection request waits for an available connection in the pool. If the wait exceeds this time, an error is returned.
PseudoColumnsSpecifies the pseudocolumns to expose as table columns, expressed as a string in the format 'TableName=ColumnName;TableName=ColumnName'.
ReadonlyToggles read-only access to Oracle Eloqua from the provider.
RetryCountThe maximum number of times to retry a Bulk API request that fails due to an HTTP 500 status code (Internal Server Error).
RetryIntervalThe time interval between attempts to retry a Bulk API request that failed with an HTTP 500 status code (Internal Server Error).
RTKSpecifies the runtime key for licensing the provider. If unset or invalid, the provider defaults to the standard licensing method. This property is only required in environments where the standard licensing method is unsupported or requires a runtime key.
TimeoutSpecifies the maximum time, in seconds, that the provider waits for a server response before throwing a timeout error.
UseBulkAPIWhether or not the bulk API is used for retrieving data.
UseConnectionPoolingEnables the connection pooling feature, which allows the provider to reuse existing connections instead of creating new ones for each request.
UserDefinedViewsSpecifies a filepath to a JSON configuration file that defines custom views. The provider automatically detects and uses the views specified in this file.
UseSimpleNamesSpecifies whether or not simple names should be used for tables and columns.

Copyright (c) 2025 CData Software, Inc. - All rights reserved.
Build 25.0.9434