Tableau Connector for Highrise

Build 25.0.9434

Configuring a Connection

After Installing the Connector you can connect and create a Data Source for data in Highrise.

Setting Up a Data Source

Complete the following steps to connect to the data:

  1. Under Connect | To a Server, click More....
  2. Select the data source called Highrise by CData.
  3. Enter the information required for the connection.
  4. Click Sign In.
  5. If necessary, select a Database and Schema to discover what tables and views are available.

Using the Connection Builder

The connector makes the most common connection properties available directly in Tableau. However, it can be difficult to use if you need to use more advanced settings or need to troubleshoot connection issues. The connector includes a separate connection builder that allows you to create and test connections outside of Tableau.

There are two ways to access the connection builder:

  • On Windows, use a shortcut called Connection Builder in the Start menu, under the CData Tableau Connector for Highrise folder.
  • You can also start the connection builder by going to the driver install directory and running the .jar file in the lib directory.

In the connection builder, you can set values for connection properties and click Test Connection to validate that they work. You can also use the Copy to Clipboard button to save the connection string. This connection string can be given to the Connection String option included in the connector connection window in Tableau.

Authenticating to Highrise

Highrise supports OAuth and API token authentication schemes.

OAuth

Highrise uses the OAuth authentication standard. To authenticate to Highrise, you need to obtain the OAuthClientId, OAuthClientSecret, and CallbackURL.

In all OAuth flows, you must set AuthScheme to OAuth. The following sections assume you have done so.

Desktop Applications

CData provides an embedded OAuth application that simplifies OAuth desktop Authentication. Alternatively, you can create a custom OAuth application. See Creating a Custom OAuth App for information about creating custom applications and reasons for doing so.

Get and Refresh the OAuth Access Token

After setting the following, you are ready to connect:

  • InitiateOAuth: Set this to GETANDREFRESH. You can use InitiateOAuth to avoid repeating the OAuth exchange and manually setting the OAuthAccessToken.
  • OAuthClientId (custom applications only): Set this to the client Id assigned when you registered your application.
  • OAuthClientSecret (custom applications only): Set this to the client secret assigned when you registered your application.
  • CallbackURL (custom application only): Set this to the redirect URI defined when you registered your application.
When you connect, the connector opens Highrise's OAuth endpoint in your default browser. Log in and grant permissions to the application. The connector then completes the OAuth process:

  1. The connector obtains an access token from Highrise and uses it to request data.
  2. The OAuth values are saved in the location specified in OAuthSettingsLocation. These values persist across connections.
The connector refreshes the access token automatically when it expires.

Headless Machines

To configure the driver to use OAuth with a user account on a headless machine, you need to authenticate on another device that has an internet browser.

  1. Choose one of two options:
    • Option 1: Obtain the OAuthVerifier value as described in "Obtain and Exchange a Verifier Code" below.
    • Option 2: Install the connector on a machine with an internet browser and transfer the OAuth authentication values after you authenticate through the usual browser-based flow, as described in "Transfer OAuth Settings" below.
  2. Then configure the connector to automatically refresh the access token on the headless machine.

Option 1: Obtain and Exchange a Verifier Code

To obtain a verifier code, you must authenticate at the OAuth authorization URL.

Follow the steps below to authenticate from the machine with an internet browser and obtain the OAuthVerifier connection property.

  1. Choose one of these options:
    • If you are using the Embedded OAuth Application, call the GetOAuthAuthorizationURL stored procedure. Open the URL returned by the stored procedure in a browser.
    • If you are using a custom OAuth application, set the following properties: Then call the GetOAuthAuthorizationURL stored procedure with the appropriate CallbackURL. Open the URL returned by the stored procedure in a browser.
  2. Log in and grant permissions to the connector. You are then redirected to the redirect URI. There will be a parameter called code appended to the redirect URI. Note the value of this parameter. Later you will set this in the OAuthVerifier connection property.
Next, you need to exchange the OAuth verifier code for OAuth refresh and access tokens.

On the headless machine, set the following connection properties to obtain the OAuth authentication values:

  • InitiateOAuth: Set this to REFRESH.
  • OAuthVerifier: Set this to the noted verifier code (the value of the code parameter in the redirect URI).
  • OAuthClientId: (custom applications only) Set this to the client Id in your custom OAuth application settings.
  • OAuthClientSecret: (custom applications only) Set this to the client secret in the custom OAuth application settings.
  • OAuthSettingsLocation: Set this to persist the encrypted OAuth authentication values to the specified location.

Test the connection to generate the OAuth settings file, then re-set the following properties to connect:

  • InitiateOAuth: Set this to REFRESH.
  • OAuthClientId: (custom applications only) Set this to the client Id assigned when you registered your application.
  • OAuthClientSecret: (custom applications only) Set this to the client secret assigned when you registered your application.
  • OAuthSettingsLocation: Set this to the location containing the encrypted OAuth authentication values. Make sure this location gives read and write permissions to the connector to enable the automatic refreshing of the access token.

Option 2: Transfer OAuth Settings

Prior to connecting on a headless machine, you need to install and create a connection with the driver on a device that supports an internet browser. Set the connection properties as described in "Desktop Applications" above.

After completing the instructions in "Desktop Applications", the resulting authentication values are encrypted and written to the location specified by OAuthSettingsLocation. The default filename is OAuthSettings.txt.

Test the connection to generate the OAuth settings file, then copy the OAuth settings file to your headless machine.

On the headless machine, set the following connection properties to connect to data:

  • InitiateOAuth: Set this to REFRESH.
  • OAuthClientId: (custom applications only) Set this to the client Id assigned when you registered your application.
  • OAuthClientSecret: (custom applications only) Set this to the client secret assigned when you registered your application.
  • OAuthSettingsLocation: Set this to the location of the OAuth settings file you copied from the machine with the browser. Make sure this location gives read and write permissions to the connector to enable the automatic refreshing of the access token.

API Token

To authenticate to Highrise with an API token, set the following:

  • AuthScheme: Set AuthScheme to APIToken.
  • APIToken: The APIToken of the user. To obtain your API token, log in to your Highrise account and click the My Info link. If you are an admin or a user, this is located under the "Settings" section of the account. See Find Your API Token in the Highrise documentation for more information.
  • AccountId: The Account Id of the user.

Next Step

See Using the Connector to create data visualizations.

Copyright (c) 2025 CData Software, Inc. - All rights reserved.
Build 25.0.9434