ODBC Driver for LinkedIn

Build 22.0.8462

Windows DSN Configuration

Using the Microsoft ODBC Data Source Administrator

You can use the Microsoft ODBC Data Source Administrator to edit the DSN configuration. Note that the DSN is created during the installation process.

Complete the following steps to edit the DSN configuration:

  1. Select Start > Search, and enter ODBC Data Sources in the Search box.
  2. Choose the version of the ODBC Administrator that corresponds to the bitness of your application (32-bit or 64-bit).
  3. Click the System DSN tab.
  4. Select the system data source and click Configure.
  5. Edit the information on the Connection tab and click OK.

Note: For .NET Framework 4.0, the driver distributes Microsoft Visual C++ 2015-2022 Redistributable. For .NET Framework 3.5, the driver distributes Microsoft Visual C++ 2008 Redistributable.

Connecting to LinkedIn

The LinkedIn CompanyId is a string of numbers, usually 6 to 9 digits long, that is unique to your company. You can find this ID in the URL of the search results page when you click on See All Jobs on your LinkedIn Page. The CompanyId is often required in queries for company data. While this may be set directly in the criteria of a query, the CompanyId may be set globally to avoid issues where the query is not so easily modified.

Authenticating to LinkedIn

OAuth

LinkedIn supports OAuth authentication only.

Desktop Applications

CData provides an embedded OAuth application that simplifies OAuth desktop Authentication. Alternatively, you can create a custom OAuth application. See Creating a Custom OAuth App for information about creating custom applications and reasons for doing so.

Get and Refresh the OAuth Access Token

After setting the following, you are ready to connect:

  • OAuthClientId (custom applications only): Set this to the client Id assigned when you registered your application.
  • OAuthClientSecret (custom applications only): Set this to the client secret assigned when you registered your application.
  • CallbackURL (custom application only): Set this to the redirect URI defined when you registered your application.
When you connect, the driver opens LinkedIn's OAuth endpoint in your default browser. Log in and grant permissions to the application. The driver refreshes the access token automatically when it expires.

Headless Machines

To configure the driver to use OAuth with a user account on a headless machine, you need to authenticate on another device that has an internet browser.

  1. Choose one of two options:
    • Option 1: Obtain the OAuthVerifier value as described in "Obtain and Exchange a Verifier Code" below.
    • Option 2: Install the driver on a machine with an internet browser and transfer the OAuth authentication values after you authenticate through the usual browser-based flow, as described in "Transfer OAuth Settings" below.
  2. Then configure the driver to automatically refresh the access token on the headless machine.

Option 1: Obtain and Exchange a Verifier Code

To obtain a verifier code, you must authenticate at the OAuth authorization URL.

Follow the steps below to authenticate from the machine with an internet browser and obtain the OAuthVerifier connection property.

  1. Choose one of these options:
    • If you are using the Embedded OAuth Application, call the GetOAuthAuthorizationURL stored procedure. Open the URL returned by the stored procedure in a browser.
    • If you are using a custom OAuth application, set the following properties:
      • InitiateOAuth: Set to OFF.
      • OAuthClientId: Set to the client Id assigned when you registered your application.
      • OAuthClientSecret: Set to the client secret assigned when you registered your application.
      Then call the GetOAuthAuthorizationURL stored procedure with the appropriate CallbackURL. Open the URL returned by the stored procedure in a browser.
  2. Log in and grant permissions to the driver. You are then redirected to the redirect URI. There will be a parameter called code appended to the redirect URI. Note the value of this parameter. Later you will set this in the OAuthVerifier connection property.
Next, you need to exchange the OAuth verifier code for OAuth refresh and access tokens.

On the headless machine, set the following connection properties to obtain the OAuth authentication values:

  • InitiateOAuth: Set this to REFRESH.
  • OAuthVerifier: Set this to the noted verifier code (the value of the code parameter in the redirect URI).
  • OAuthClientId: (custom applications only) Set this to the client Id in your custom OAuth application settings.
  • OAuthClientSecret: (custom applications only) Set this to the client secret in the custom OAuth application settings.
  • OAuthSettingsLocation: Set this to persist the encrypted OAuth authentication values to the specified file.

Test the connection to generate the OAuth settings file, then re-set the following properties to connect:

  • InitiateOAuth: Set this to REFRESH.
  • OAuthClientId: (custom applications only) Set this to the client Id assigned when you registered your application.
  • OAuthClientSecret: (custom applications only) Set this to the client secret assigned when you registered your application.
  • OAuthSettingsLocation: Set this to the file containing the encrypted OAuth authentication values. Make sure this file gives read and write permissions to the driver to enable the automatic refreshing of the access token.

Option 2: Transfer OAuth Settings

Prior to connecting on a headless machine, you need to install and create a connection with the driver on a device that supports an internet browser. Set the connection properties as described in "Desktop Applications" above.

After completing the instructions in "Desktop Applications", the resulting authentication values are encrypted and written to the path specified by OAuthSettingsLocation. The default filename is OAuthSettings.txt.

Test the connection to generate the OAuth settings file, then copy the OAuth settings file to your headless machine.

On the headless machine, set the following connection properties to connect to data:

  • InitiateOAuth: Set this to REFRESH.
  • OAuthClientId: (custom applications only) Set this to the client Id assigned when you registered your application.
  • OAuthClientSecret: (custom applications only) Set this to the client secret assigned when you registered your application.
  • OAuthSettingsLocation: Set this to the path to the OAuth settings file you copied from the machine with the browser. Make sure this file gives read and write permissions to the driver to enable the automatic refreshing of the access token.

Copyright (c) 2023 CData Software, Inc. - All rights reserved.
Build 22.0.8462